  • Configure DRAC network parameters
racadm getconfig -g cfgLanNetworking
racadm config -g cfgLanNetworking -o cfgNicUseDhcp 0
racadm config -g cfgLanNetworking -o cfgNicIpAddress 166.38.84.157
racadm config -g cfgLanNetworking -o cfgNicNetmask 255.255.255.128
racadm config -g cfgLanNetworking -o cfgNicGateway 166.38.84.254
racadm config -g cfgLanNetworking -o cfgDNSServer1 166.37.218.90
racadm config -g cfgLanNetworking -o cfgDNSServer2 166.33.193.132
racadm config -g cfgLanNetworking -o cfgDNSRacName ndceomp2b
racadm config -g cfgLanNetworking -o cfgDNSDomainName vzbi.com
racadm getconfig -g cfgLanNetworking
  • upload custom certificate
racadm sslcertupload -t 2 -f CA.pem 
racadm sslkeyupload -t 1 -f ndceomp2b.key
racadm sslcertupload -t 1 -f ndceomp2b.crt
  • user management
racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword 123456
racadm config -g cfgUserAdmin -i 10 -o cfgUserAdminUserName admin
racadm config -g cfgUserAdmin -i 10 -o cfgUserAdminPassword password
racadm config -g cfgUserAdmin -i 10 -o cfgUserAdminEnable 1
racadm config -g cfgUserAdmin -i 10 -o cfgUserAdminPrivilege 0x000000f9
racadm config -g cfgUserAdmin -i 10 -o cfgUserAdminIpmiLanPrivilege 4